Tento e-shop využívá cookies

Na našich webových stránkách používáme soubory cookies. Některé z nich jsou nezbytné, zatímco jiné nám pomáhají vylepšit tento web a váš uživatelský zážitek. Souhlasíte s používáním všech cookies?

Cookies nastavení

Vaše soukromí je důležité. Můžete si vybrat nastavení cookies níže.

Eam1104I (EarI)

Kód produktu: ER0231 Kód výrobce: ER0231 Kód dodavatele: {748DC7D7-D5B0-4049-A187-00BDDB5EFEAA} Výrobce: Life Technologies Czech Republic s.r.o.
1 672,22 Kč
1 382,00 Kč bez DPH
do týdne
300 Units

5'...C T C T T C (N)1...3'
3'...G A G A A G (N)4...5'

Zobraz detailní popis

Detailní popis

Thermo Scientific conventional restriction endonucleases are a large collection of high quality restriction enzymes, optimized to work in one of the buffers of the Five Buffer System. In addition, the universal Tango buffer is provided for convenience in double digestions. All of the enzymes exhibit 100% activity in the recommended buffer and reaction conditions. To ensure consistent performance, Thermo Scientific restriction enzyme reaction buffers contain premixed BSA, which enhances the stability of many enzymes and binds contaminants that may be present in DNA preparations.

Highlights

  • Superior quality – stringent quality control and industry leading manufacturing process
  • Convenient color-coded Five Buffer System
  • Includes universal Tango buffer for double-digestions
  • BSA premixed in reaction buffers
  • Wide selection of restriction endonuclease specificities

Applications

  • Molecular cloning
  • Restriction site mapping
  • Genotyping
  • Southern Blot
  • Restriction fragment length polymorphism (RFLP)
  • SNP

Note

Certain sites in lambda DNA are difficult to cleave with Eam1104I, the same as with its prototype Ksp632I.

For methylation sensitivity refer to product specifications.

Conditions for 100% Activity
  • 1X Buffer Tango: 33 mM Tris-acetate (pH 7.9 at 37°C), 10 mM Mg-acetate, 66 mM K-acetate, and 0.1 mg/mL BSA
  • Incubate at 37°C
Digestion of agarose-embedded DNA Minimum 5 units of the enzyme are required for complete digestion of 1 µg of agarose-embedded lambda DNA in 16 hours.
Double Digestion Perform double digestion using DoubleDigest.
Hazardous No
Isoschizomers Search for commercial isoschizomers using REsearch.
Storage Buffer Eam1104I is supplied in: 10 mM Tris-HCl (pH 7.4 at 25°C), 100 mM KCl, 1 mM DTT, 1  mM EDTA, 0.2 mg/mL BSA, and 50% (v/v) glycerol.
Storage Condition -20 C

Reaction conditions

Recommended buffer for 100% activity Optimal temperature Enzyme activity in Thermo Scientific buffers, % Tango buffer for double digestion
B (blue)
1X
G (green)
1X
O (orange)
1X
R (red)
1X
Tango
(yellow)
1X / 2X
Tango 37°C 50-100 50-100 0-20 0-20 100 0-20 1X

Methylation Effects

  • Dam: never overlaps - no effect.
  • Dcm: never overlaps - no effect.
  • CpG: may overlap - no effect.
  • EcoKI: never overlaps - no effect.
  • EcoBI: may overlap - effect not determined.
Methylation type Sequence Cleavage effect
CpG 5'...CTCTTm5C G...3'
3'...GAGAA Gm5C...5'
No effect

Cleavage efficiency close to the termini of PCR fragments

bp from the recognition site to fragment end
1 2 3 4 5
0 50-100

Number of recognition sites in DNA molecules

Lambda ΦX174 M13mp18/19 pBR322 puc18/19 pUC57
34 2 2 2 3 3
pTZ19R/U pTZ57R pBluescriptIIKS(-/+) pBluescriptIISK(-/+) pACYC177 pACYC184
3 3 3 3 2 1

 

Hodnocení produktu

Produkt zatím nikdo nehodnotil, buďte první!