Tento e-shop využívá cookies

Na našich webových stránkách používáme soubory cookies. Některé z nich jsou nezbytné, zatímco jiné nám pomáhají vylepšit tento web a váš uživatelský zážitek. Souhlasíte s používáním všech cookies?

Cookies nastavení

Vaše soukromí je důležité. Můžete si vybrat nastavení cookies níže.

ORA™ qPCRProbe Mix

Kód produktu: QPP0101 Kód výrobce: QPP0101 Kód dodavatele: {2E9A922A-ACE5-4B9A-9E42-458B50C47B3D} Výrobce: highQu GmbH professionally simple
-4 %
Ušetříte
156,70 Kč
4 230,77 Kč
4 074,07 Kč
3 367,00 Kč bez DPH
do týdne
200

highQu qPCR mastermixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates, in multiplexing and guaranty rapid extension with early Ct values with minimum or no optimization.

Zobraz detailní popis

Detailní popis

Applications


  • qPCR assays based on specific probes:

  • TaqMan®, Molecular Beacons, Scorpions™ Probes

  • Gene expression analysis, quantification of:

  • gDNA, cDNA, viral DNA, low copy number genes





  •  
  •  
  •  
  •  

Benefits


  • Universal - both standard and fast cycling, all probe qPCR assays

  • qPCR of GC or AT rich templates, single-plex & multiplexing

  • Rapid extension, early Ct

  • Supplied with PCR Water

  • Bulk quantities & custom packaging available

highQu qPCR mastermixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates, in multiplexing and guaranty rapid extension with early Ct values with minimum or no optimization.

Our mastermixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the ORA™ qPCR Probe Mastermixes are available in three versions – without ROX, with low or high ROX concentration.

Important Notes
  • Use special primer selection programs for good planning.
  • Work with amplicons in a range of 80-200, max 400 bp.
  • Take typical measures to prevent PCR cross over contamination, keep your bench clean, wear gloves, use sterile tubes and filter pipet tips.
  • Run reactions in triplets; include a no-template control and positive control in parallel.
  • Thaw and keep reagents on ice. Mix well before use.
 
Prepare a 20 µl reaction:
Reverse Primer 100 - 400 nM final c.
Forward Primer 100 - 400 nM final c.
Specific Probe 200 nM final c.
cDNA Template or
gDNA Template
<100 ng or
<1 μg
PCR Water to 10 μl
ORA™ qPCR Mix, 2X 10 μl

 

  • Mix gently, avoid bubbles.
  • Place into the instrument set like:

 

Initial denaturation 1 cycle: 95°C - 2 min for cDNA  or
1 cycle: 95°C - 3 min for gDNA
Denaturation 40 cycles: 95°C - 5 sec
Anneal./extension 40 cycles: 60-65°C - 20-30 sec

 

  • Follow instrument instructions for melt curve analysis.
  • CAT.

    SIZE COMPONENTS COMPOSITION
    QPP0101 200 r
    of 20 µl
    2 x 1 ml - ORA™ qPCR Probe Mix, 2X
    2 x 1 ml - PCR Water
    Hot Start qPCR components: dNTPs at 0.25 mM, optimized buffer, ROX is not included.
    QPP0105 1000 r
    of 20 µl
    10 x 1 ml - ORA™ qPCR Probe Mix, 2X
    10 x 1 ml - PCR Water
    Hot Start qPCR components: dNTPs at 0.25 mM, optimized buffer, ROX is not included.

     

    Storage

     

    In the dark at -20°C.